Angel Care AC401 Owner's Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 50
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
14
Note: Test your Angelcare® monitor BEFORE using it for the first time and then on a regular basis to make sure that it is functioning properly.The
Angelcare® monitor can be used outside of the crib in a different sleeping area.Test your monitor when moving the sensor pad to a new location
to ensure sensitivity is adjusted correctly to the new padding or mattress. Consult the movement sensitivity adjustment section (step 6).
1.TEST THE SOUND Switch the Parent Unit to the “Sound Only”function. Have someone else speak into the nursery unit or place a radio near the
nursery unit. You should hear sound from the Parent Unit. If there is no sound,refer to the Troubleshooting section.
2.TEST YOUR MONITOR TO DETECT MOVEMENT Make sure the sensor pad's cord is plugged into the nursery unit then turn both units ON. Set
the Parent Unit on the“Movement only” function. Gently move your hand on the mattress.The top green light (with pendulum symbol) will flash
on the nursery unit with your every movement. Remove your hand from the mattress. Due to the lack of movement, a “pre-alarm “Tic”sound will
be emitted after 15 seconds and 5 seconds later, the alarm will sound and the green lighton the nursery unit will turn off.
3. TEST THE STOPPING OF THE ALARM To stop the alarm, place your hand lightly on the mattress so that the sensor pad starts detecting
movement again.The green light with the pendulum icon will start flashing again, as movement is detected by the sensor pad. You may also shut
the nursery unit OFF and turn it ON again to stop the alarm.
NOTE: If the alarm does not sound, the sensor pad may be detecting a continuous vibration from the floor, a strong draft or the crib is being
touched. Avoid contact with crib when monitor is in use. Place crib near a solid supporting wall and away from strong air currents. The sensitivity
of the sensor pad may need to be reduced,consult the movement sensitivity adjustment STEP 2.
4.VERIFYING THE BATTERY MODE Verify that the battery mode is functional by operating both units without the AC adapters. If the green light on
the nursery unit does not light up, the batteries need to be replaced. If the Parent Unit doesn’t light up and the screen does not appear, it needs
to be recharged.
STEP 12
ADDITIONAL FUNCTIONS
CHANNEL SELECTION:
If the transmission is not clear, or if you hear parasite sounds, you should change the
channel. Press and hold the SELECT button to change the channel (with the arrows). Then
press the SELECT button again to confirm.
TEMPORARY MUTE:
If you want to mute the sound for 2 minutes, press the center EXIT button. To reactivate the
sound before the 2 minutes have elapsed, press EXIT again. You can also turn the alarm off
by pressing the same button (this does not apply to the low battery alarm).
HOLD:
Press and hold the down volume arrow for 2 second. This symbol “H” will apear on the
Parent Unit display. This function allows you to put the monitor on Hold when you need to
pick the baby out of the crib for a short period of time. During this period, the movement
alarm will not go off, nor the sound will be transmitted. A double beep will be heard every
minute to let you know the monitor is on Hold. To void this function, press and hold the down
volume arrow for 2 second. The display will revert to normal.
Note: When there is a movement alarm, press any key to put the monitor on HOLD. During
SOUND ONLY mode, the HOLD function is not active.
•CONNECTING THE PARENT UNIT TO THE NURSERY UNIT:
If you lose the connection between the 2 units,turn them both off. Turn ON the Parent Unit and
press and hold the MENU button ,the "out of range"indicator will flash and you will hear a
beep.Turn ON the nursery unit and press and hold the top button of the nursery unit to re-
connect.The Tic light flashes.This normally happens within a few seconds and you will hear a bleep
to confirm it. If successful, the Parent Unit display will first show the channel of transmission (C1
to C8), which will be replaced by the room temperature and icons for all activated functions.
Note : The connecting process should be done within 30 seconds. If longer, the operation will be
ignored and you will have to start over.
• PAGING:
If you want to locate the Parent Unit, press the top button of the nursery unit.
Low battery indicator
The monitor will revert to battery mode during a power failure only if batteries are inserted
in both units.
It is also possible to use the Angelcare© monitor in places where electricity is not available.
When the nursery unit’s low battery RED light is flashing, its batteries need to be replaced.
On the screen of the Parent Unit, the battery icon flashes and the nursery unit icon appears.
A short BEEP will also be heard every 15 seconds for about 30 minutes, until the unit shuts
itself off.
Parent Unit should be recharged when icon is clear (will not flash) and a beep sound is
heard. A short BEEP sound will be heard every 15 seconds until the unit shuts itself down.
Note: Do not use Alkaline batteries in the Parent Unit.
IMPORTANT : If the “Out of range” function is ON, when the nursery unit shuts itself off, the
“Out of range” signal will be heard and displayed on the Parent Unit.
Low battery
indicator
Red light
STEP 11
BATTERY MODE AND WARNINGS
STEP 13
ADDITIONAL FUNCTIONS
TESTING YOUR ANGELCARE
®
MONITOR