Angel Care AC401 Owner's Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 50
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
11
HOW TO OPERATE YOUR ANGELCARE
®
MONITOR
Charger adapter
socket
STEP 1
Connect the long sensor pad cord into the nursery unit.
Insert 4 AAA regular batteries (not included) into nursery unit (for battery
backup in case of power failure).
Connect AC adapter to nursery unit and plug adapter into an electrical
outlet in the baby’s room.
After both units are properly installed you may adjust the sensor pad
sensitivity level. The sensitivity dial shows the level 1 to 5, where 1 is less
sensitive and 5 very sensitive. It is preset between level 2,5 and 3. Should
there be a false alarm, increase the sensitivity by a half level during testing
until it works perfectly for your mattress and bed size.
Insert 4 AAA NIMH rechargeable batteries (included) into Parent Unit.
NEVER use regular alkaline batteries, they may explode.
Connect AC adapter to Parent Unit charger and plug adapter into an
electrical outlet. Let charge for 15 continuous hours before using the
monitor for the first time.
Charger adapter
socket
Sensor pad cord
socket
Adapter socket
Sensor pad
sensitivity dial
1 sensor pad 2 sensor pads
POSITION OF SENSOR PAD UNDER MATTRESS
Crib center Crib center
Position the sensor pad as shown above. Make sure the printed side faces up. Do NOT place any bedding between the mattress
and the sensor pad.
Secure the sensor pad cord to crib using a tie wrap. Run the cord on the floor to ensure it is out of the baby’s reach.
•The Sensor Pad must rest on a completely flat and firm surface. If the crib has a spring or slat base, place a hard board between
the crib base and the Sensor Pad measuring at least 13” x 13” (33x33 cm) and 1/4 inch (6 mm) thick. Make sure the sensor
pad’s cord passes underneath the mattress as shown above.
• The sensor pad works with all baby bed sizes and all mattresses, except memory foam mattresses.You will have to test your
sensor pad on STEP 13.
• Once you are done using the Sensor Pad, please remove it from the baby’s crib and store it away.
The Angelcare Sensor Pad feature is not designed for use with adults, children or infants older than 24 months.
IMPORTANT
Keep at
least 1m
(39 inches)
apart
Sensor Pad(s) 1 or 2
INSTALLATION OF THE SENSOR PAD UNDER THE MATTRESS
STEP 2
INSTALLATION OF THE NURSERY UNIT
Battery
compartment
STEP 3
INSTALLATION OF THE PARENT UNIT
Battery
compartment
(On some models)
WARNING
STRANGULATION HAZARD - Children have STRANGLED in cords. Keep the adapter cords and
sensor pad cord out of the reach of children. Do not put the Nursery Unit inside a crib or play
yard. Because of the serious strangulation risk to infants and toddlers, parents and caregivers
should never place the nursery unit within 3 feet (1 meter) of a crib. NEVER use extension
cords with AC adapters. ONLY use the AC adapters provided.
AC401 NA 13 12 2012_AC401inter 042008 12-12-19 8:48 AM Page 11
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 49 50

Comments to this Manuals

No comments